Clause 1
Declared operating environment
The supplier shall declare that the proposed monitoring system is suitable for the stated use case and the Coastal salt climate profile, including the environmental stressors listed in this specification.
Step 3 — final specification
Use case + climate profile = final specification. This version applies the smart-city climatology use case to the Coastal salt climate profile.
Copy the clauses below into the tender document, then replace any bracketed placeholders with project-specific values, legal language, and approved thresholds.
Clause 1
The supplier shall declare that the proposed monitoring system is suitable for the stated use case and the Coastal salt climate profile, including the environmental stressors listed in this specification.
Clause 2
The complete station shall meet the following minimum environmental limits: -20 °C to +55 °C, wind-driven rain, salt-laden humidity, and coastal corrosion exposure.
Clause 3
The supplier shall use corrosion-resistant materials, sealed connectors, protected cable routing, and mounting details suitable for salt-laden environments. Bare dissimilar-metal junctions exposed to weather shall not be accepted without justification and protection.
Clause 4
The bidder shall submit corrosion-resistance evidence, material specifications, connector sealing details, grounding design, and maintenance instructions suitable for coastal salt exposure.